2751076 - K15 CLOCK NOT WORKING

With the ignition ON, the display does not display the time correctly or at all.
Results of the tests
1INSTRUMENT PANEL FUNCTIONS CHECKAll OKProblems metOperation

Check:

  • That the display shows the correct time
  • That it is possible to adjust the time
  • That the clock moves forward
  • That the instrument panel light dimmer has not been selected.
  • That the mode button has not been pressed.
  • That there are no failure messages displayed.
Continue to Step 2The time displayed is not correctAdjust the time
The time cannot be adjustedContinue to Step 2
The clock is stuckReplace instrument panel Op. 5560B11
The time is not displayed because there are priority messages or adjustments in progress.Remove the cause of the priority messages
The display/time cannot be seen properlyContinue to Step 2
2CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the Examiner equipment to the diagnostic socket and check that there are no faults Continue to Step 3There are errorsContinue according to the instructions for the diagnostic equipment
3CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Keeping the Examiner connected to the diagnostic socket, check the operation of the display in active diagnosisContinue to Step 4Defective displayReplace instrument panel Op. 5560B11
4CHECK ON ELECTRICAL CIRCUITAll OKProblems metOperation
Check instrument panel power supply and earth See   E4010  INSTRUMENT PANEL Continue to Step 5Connections defective, earth or supply defectiveRestore the correct connections, if necessary, replace the wiring See   E4010  INSTRUMENT PANEL
5CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosis.