2751077 - K16 CITY WARNING LIGHT ON

After having carried out the initial test, the CITY warning light in the Instrument Panel Node should remain on constantly.
Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation
Press the button repeatedly to check whether the problem is due to an incorrect setting and check whether the LED in the button changes state.Continue to Step 11Incorrect CITY function setting.Restore the correct function.
The LED in the button does not change state. Continue to Step 6
The LED in the button lights up and then goes out. Continue to Step 1
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner check, in the Instrument Panel Node ambient, that there are no errors and the following parameters are present. Continue to Step 5Impossible to connect with the Instrument Panel control unitContinue to Step 2
There are errors Continue according to the instructions for the diagnostic equipment
2ELECTRICAL POWER SUPPLY CHECKAll OKProblems metOperation
Check that the Instrument Panel Node electrical power supply is correct. Continue to Step 3Positive and/or earth electrical power supply fault. Replace the defective component (if a fuse is involved, search for the cause of the problem).
3CHECK ELECTRICAL CONNECTIONSAll OKProblems metOperation
Check the electrical connections between the Body Computer and the Instrument Panel, in particular that each individual pin is correctly connected. Continue to Step 4Electrical connections not working.Restore damaged electrical connections.
4CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner, check whether it is possible to connect with the Instrument Panel Node. Continue to Step 6Impossible to connect with the Instrument Panel control unit.Replace the Instrument Panel Node control unit.
5CHECK WITH ACTIVE DIAGNOSISAll OKProblems metOperation
With the Examiner in Instrument Panel Node ambient, check, in Active Diagnosis, that the driving warning light is correctly activated Continue to Step 6The component in question is not activated. Replace the Instrument Panel Node control unit
6CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner, check, in the Body Computer Node ambient, that there are no errors and that the specific parameter varies.Continue to Step 1Impossible to connect with the Body Computer control unit.Continue to Step 7
There are errors Continue according to the instructions for the diagnostic equipment
The parameter values do not changeContinue to Step 10
7ELECTRICAL POWER SUPPLY CHECKAll OKProblems metOperation
Check that the Body Computer Node electrical power supply is correct. Continue to Step 8Positive and/or earth electrical power supply fault. Replace the defective component (if a fuse is involved, search for the cause of the problem).
8CHECK ON CONNECTIONSAll OKProblems metOperation
Check the continuity of the wiring between the CITY button and the Body Computer Node See   E7045  ELECTRIC STEERING Continue to Step 9Electrical connections not working.Restore damaged electrical connections.
9CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner, check the possibility of connecting with the Body Computer Node. Continue to Step 6Impossible to connect with the Body Computer control unit.Replace the Body Computer Node
10CHECK ON CONNECTIONSAll OKProblems metOperation
Check that the CITY button and the wiring with the Body Computer Node are working properly. See   E7045  ELECTRIC STEERING Continue to Step 11Button faulty Replace faulty component
Electrical wiring not workingRenew the damaged wiring.
11CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer present End of diagnosisFault persistsContinue to Step 1