Connect the diagnostic equipment (Examiner
Plus or Smart) and carry out active diagnosis 'Zeroing phonic wheel
initialisation'.Bring the engine up to temperature (temperature greater
than 80° Χ) from minimum level.Accelerate to 5000 rpm (constant) for about
2-3 seconds and release. Carry out this operation for three consecutive
times.With the ignition off, wait 45 s before
re-starting the engine (Power Latch function).