169000653 - Z83 SUPPLY VOLTAGE ERROR

The diagnostic equipment signals the following error: "C1800 - Supply voltage"
This error is signalled if the control unit detects a battery voltage that is too high or too low
1POWER SUPPLY CIRCUIT CHECKAll OKProblems encounteredOperation
Check that the supply voltage at the battery terminals is correct.Check the power supply wiring from the battery to the ABS control unit See E7020 ABS there should be no drop in voltage between the battery and the control unitMove on to Step 2 1

  • Battery voltage not correct
  • Drop in voltage in the wiring

2CHECK ON CORRECT OPERATIONAll OKProblems encounteredOperation
Delete the errors using the diagnostic equipment.Carry out a road test    See Test 3340OA A.B.S. SYSTEM ACTUATION CHECKto ensure that the control unit checks whether there are any errors still present.Return to the workshop and check that the fault is no longer present using the diagnostic equipment.End of diagnosis