2751078 - K17 CITY WARNING LIGHT OFF (INITIAL TEST NOT CARRIED OUT)

After having carried out the initial test on the Instrument Panel Node, the CITY warning light remains off constantly.
Results of the tests
1PRELIMINARY CHECKAll OKProblems metOperation
Press the button repeatedly to check whether the LED in the button changes state.Continue to Step 2The LED in the button does not change state. Continue as described in See table   K16 
2CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner check, in the Instrument Panel Node ambient, that there are no errors and the following parameters are present. Continue to Step 6Impossible to connect with the Instrument Panel control unitContinue to Step 3
Impossible to connect with the Instrument Panel control unitContinue according to the instructions for the diagnostic equipment.
3ELECTRICAL POWER SUPPLY CHECKAll OKProblems metOperation
Check that the Instrument Panel Node electrical power supply is correct. Continue to Step 4Positive and/or earth electrical power supply fault. Replace the defective component (if a fuse is involved, search for the cause of the problem).
4CHECK ELECTRICAL CONNECTIONSAll OKProblems metOperation
Check the electrical connections between the Body Computer and the Instrument Panel, in particular that each individual pin is correctly connected. Continue to Step 5Electrical connections not working.Restore damaged electrical connections.
5CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner, check whether it is possible to connect with the Instrument Panel Node. Continue to Step 7Impossible to connect with the Instrument Panel control unit.Replace the Instrument Panel Node control unit.
6CHECK WITH ACTIVE DIAGNOSISAll OKProblems metOperation
With the Examiner in Instrument Panel Node ambient, check, in Active Diagnosis, that the driving warning light is correctly activated Continue to Step 7The component in question is not activated. Replace the Instrument Panel Node control unit
7CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer present End of diagnosisFault persistsContinue to Step 1