2751099 - K90 INSTRUMENT LIGHTS / NOT WORKING

.
Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

With the diagnostic equipment (Examiner or other instruments) connected. Check the following on the CAN information network:

  • for inactive control units;
  • control unit errors;
  • absence of control unit with error in CAN line
Continue to Step 2Presence of faults Continue following the instructions for the diagnostic equipment
2CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check the operation of the panel lighting at the instrument panel node through active diagnosis Continue to Step 3Instrument panel does not light upReplace instrument panel Op. 5560B11
3Continue as instructed by the testerAll OKProblems metOperation
Check that the fault is no longer present End of diagnosisFault persistsReplace the Body Computer Op.   5505A32