2752607 - 1060G16 pressure relief sensor - r r

Removing ( Refitting ) Disconnect the battery negative terminal.1. Disconnect the electrical connection from the air flow meter.

NameConnector
1Air flow meter K41
2. Loosen the band and disconnect the air inlet hose to the turbocharger.
1. Remove the air filter (1a) complete with air flow meter (1b) by releasing from the underlying pins and then from the rear fastenings.
1. Release the electrical wiring (1a) from the band (1b) and move it aside.2. Disconnect the electrical connection from the excess pressure sensor.

NameConnector
2Turbocharging sensor K82
3. Undo the bolt (3a) and remove the over-pressure sensor (3b).
Refitting ( Removing ) Fit the excess pressure sensor in place and fix it using the bolt.Connect the electrical connection to the excess pressure sensor.

NameConnector
-Turbocharging sensor K82
Fit the electrical wiring in place and fasten it using the band.Fit the air filter complete with air flow meter in place.Connect the air inlet hose to the turbocharger and tighten the band.Connect the electrical connection to the air flow meter.

NameConnector
-Air flow meter K41
Connect the battery negative terminal.