2752846 - 5010A12 engine/heater line - r r

Removing ( Refitting ) Disconnect the battery negative terminal.1. Disconnect the electrical connection from the air flow meter.

NameConnector
1Air flow meter K41
2. Loosen the band and disconnect the the turbocharger air inlet sleeve from the rigid pipe, air flow meter side.
1. Remove the air filter (1a) complete with air flow meter (1b) by releasing from the underlying pins and then from the rear fastenings.
1. Open the fastening band (1a) and release the pipe (1b).
1. Opening the fastening band (1a) and release the power unit coolant pipe (1b) and remove it.
Refitting ( Removing ) Fit the power unit coolant pipe in position.Renew the fastening bands.Renew the metal bands fastening the pipe to the heater and to the EGR. - 0010T21  coolant check density and top up if necessaryFit the air filter complete with air flow meter in place.Connect the air intake sleeve to the turbocharger, air flow meter side, and tighten the band.Connect the electrical connection to the air flow meter.

NameConnector
-Air flow meter K41
Connect the battery negative terminal.