2752886 - 5040B30 expansion valve (tube orifice) - r+r

1. Disconnect the electrical connection from the air flow meter.

NameConnector
1Air flow meter K41
2. Loosen the band and disconnect the the turbocharger air inlet sleeve from the rigid pipe, air flow meter side.
1. Remove the air filter (1a) complete with air flow meter (1b) by releasing from the underlying pins and then from the rear fastenings.
 - 0010T84  coolant for air conditioning system dehydrate and recharge1. Unscrew the retaining nuts.2. Disconnect the air conditioning pipes from the expansion valve.
1. Undo the fixing bolts (1a) and remove the expansion valve (1b).
Refitting ( Removing ) Fit the expansion valve in place and tighten the fixing bolts.Connect the air conditioning rigid pipes to the expansion valve and tighten the fixing nuts. - 0010T84  coolant for air conditioning system dehydrate and recharge Fit the air filter complete with air flow meter in place.Connect the air intake sleeve to the turbocharger, air flow meter side, and tighten the band.Connect the electrical connection to the air flow meter.

NameConnector
-Air flow meter K41