184001384 - 5040D75 AIR CONDITIONER RECIRCULATION FLAP CONTROL MOTOR R R

Removing ( Refitting ) 7040A19 cushion padding - r r 1. Unscrew the motor retaining bolt.2. Disconnect the motor electrical connection.
NameConnector
2Outside / recirculation air intake flap actuator N82
3. Remove the motor releasing the intake.
Refitting ( Removing ) Check that the motor is undamaged.Position the motor engaging the intake in the compulsory position.Tighten the bolts fixing the motor.Connect the motor electrical connection. 7040A19 cushion padding - r r Carry out the system zeroing procedure using the Examiner.