184001386 - 5040D86 AIR CONDITIONER RIGHT HAND AIR MIXER FLAP CONTROL MOTOR - R R

Removing ( Refitting ) 7040A19 RIVESTIMENTO INFERIORE DESTRO plancia - S.R. 1. Undo the bolts fixing the motor.2. Disconnect the electrical connection for the motor.
DescriptionConnector
2Right mixed air flap actuator N79
3. Remove the motor releasing the intake. Refitting ( Removing ) Check that the motor is not damaged.Position the motor attaching the intake in the correct position.Tighten the bolts fixing the motor.Connect the electrical connection for the motor. 7040A19 RIVESTIMENTO INFERIORE DESTRO plancia - S.R. Carry out the system zeroing procedure using the Examiner.