184000985 - 1064B34 TURBO CHARGING PRESSURE CONTROL SOLENOID (TIMED OVERBOOST) - R + R

Removing ( Refitting ) Proceed with removal    Op. 5530B10 BATTERY - R+R.Proceed with removal    Op. 5530B52 BATTERY DRIP TRAY/SUPPORT - R.R..1. Disconnect the electrical connection from the air flow meter.

NameConnector
1Air flow meter K41
2. Press on the retaining tab and release the turbocharging pressure control solenoid.3. Disconnect the electrical connection from the turbocharging pressure solenoid valve.

NameConnector
3OVERBOOST solenoid valve L36
4. Loosen the collars, disconnect the pipes (4a) and remove the solenoid valve for the turbocharger vanes actuator (4b).
Refitting ( Removing ) Connect the pipes to the solenoid valve for the turbocharger vanes actuator.Connect the electrical connection to the turbocharging pressure solenoid valve.Secure the turbocharging pressure solenoid valve and secure with the tab.Connect the electrical connection to the air flow meter.Proceed with refitting    Op. 5530B52 BATTERY DRIP TRAY/SUPPORT - R.R..Proceed with refitting    Op. 5530B10 BATTERY - R+R.