The connection for the radiotaxi
D57
receives a direct supply from the battery via the line for the specific
fuse
B57
and is suitably earthed.
The connection for the taxi-meter
D55
receives a direct supply from the battery - pin 6 - via the line
for the specific fuse
B55
and the maxifuse
J/B2
of
B5
.and is suitably earthed.
It receives a supply when the ignition is
switched on (INT) - pin 4 - via the line for bridge fuse
B26.
Pin 2 receives a supply, with the side lights
on, via the line protected by fuse
F2 of the junction unit B1
(
See
E2010
SIDE LIGHTS / NO. PLATE LIGHTS
).
Pin 5 of connection
D55
is earthed.
Pin 1 receives the speedometer signal from
the instrument panel
E50
- pin 31 of connector A.
Pin 3 of
D55
sends a supply, with
the side lights on, to the connection for the TAXI sign
D56
,