|  |  | Results of the tests | 
| 1 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
|---|
|  | Connect
the diagnostic equipment (Examiner or other instruments) to the
diagnostic socket Check, in order: no faults in the alarm control unitno faults in the alarm receiver
 | Continue to Step 2 | Error detected in the
control unit or receiver | Continue according to the instructions for
the diagnostic equipment | 
| Dialogue failure for diagnostic equipment between the control
unit and the receiver | Restore the connection between the control unit and the
diagnostic connector ( See   E7015  ALARM ). | 
| 2 | ACTIVE DIAGNOSIS WITH DIAGNOSTIC
EQUIPMENT | All
OK | Problems
met | Operation | 
|---|
|  | With
the diagnostic equipment (Examiner or other instruments) carry out
the active diagnosis of the operation of the siren | Continue to Step 3 | Siren not activated | Check and, if necessary,
replace the alarm control unit  Op.   5580E46   . | 
| 3 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
|---|
|  | Check
that the fault is no longer present | End of diagnosis | Fault persists | Search for the
fault starting from another symptom' |