2888317 - A25 ALARM VOLUMETRIC SURVEILLANCE NOT WORKING

When the alarm is operated the volumetric surveillance does not work
tt is possible to exclude volumetric surveillance from system operation ( see DESCRIPTION AND OPERATION: 5580E  anti-theft device).
Results of the tests
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket

Check, in order:

  • no faults in the alarm control unit
  • no faults in the alarm receiver
Continue to Step 2Error detected in the control unit or receiverContinue according to the instructions for the diagnostic equipment
Dialogue failure for diagnostic equipment between the control unit and the receiverRestore the connection between the control unit and the diagnostic connector ( See   E7015  ALARM ).
2CHECK VOLUMETRIC SENSORSAll OKProblems metOperation

Check, in order:

  • operation of volumetric sensors
  • connections between sensors and alarm control unit
See   E7015  ALARM ).
Continue to Step 3Sensor faultyReplace sensor Op.   5580E22  .
Connections brokenRestore the connections
3CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'