2888417 - L11 CLIMATE CONTROL WORKING IRREGULARLY

The control unit operates the fan which sends air into the passenger compartment normally, with the pre-set flows, but this air sometimes makes the temperature in the passenger compartment too low and sometimes too high.
Results of the tests
1SYSTEM OPERATION CHECKAll OKProblems metOperation
Check that the system cooling is correct: See Test   5040A  Checking operation of air conditioner (temperature) Continue to Step 2The temperature decreases very slowly: insufficient fluid:Re-pressurize the system: Op.   5040A10 
2SYSTEM PRESSURE CHECKAll OKProblems metOperation
Check the system pressure: See Test   5040B  Check on operation of air conditioning system (pressures) Continue to Step 3High pressure does not increase or low pressure decreases too much: leaks in the circuitLocate the leaks Op.   5040A14 
High pressure correct, low pressure very highReplace the expansion valve Op.   5040B30 
High pressure high, low pressure below normalClean or replace the drier filter Op.   5040A44 
Pressure trends irregular: pipes obstructedWash the system, see Op.   5040A10 
Pressure trends irregular: evaporator obstructed.Replace the evaporator: Op.   5040C64 
3CONDENSER CHECKAll OKProblems metOperation
Visually inspect the condition of the condenser: the heat exchange surface should not be dirty or fouledContinue to Step 4Condenser dirtyClean the condenser if necessary, replace it: Op.   5040A40 
4CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'