2888432 - N02 SUPPLEMENTARY POWER POINTS NOT WORKING

With the ignition key in the ON position, when a consumer is connected to the special current socket, it does not work.
The power sockets all have a heat protection device: if devices with high energy absorption are connected, this protection cuts off the supply.
Results of the tests
1CURRENT SOCKET CHECKAll OKProblems metOperation
Check the current socket: in particular, make sure that the thermal protection device inside the socket has not been affected due to overloadingContinue to Step 2Thermal protection in the dashboard socket affectedReplace the thermal protection or the current socket Op.   7065C84 
Thermal protection in the rear socket affectedReplace the thermal protection or the current socket Op.   7065C86 
2CURRENT SOCKETS ELECTRICAL CIRCUIT CHECKAll OKProblems metOperation

Check, in order:

  • current sockets fuse
  • services relay
  • current sockets supply and earth
See   E3070  CIGAR LIGHTER / CURRENT SOCKET
Continue to Step 3Component defectiveReplace the component involved (if a fuse is involved, search for the cause of the problem)
Connections not correctRestore the connections
3CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'