2888487 - W01 HIGH CO EMISSIONS

The percentage of CO and/or HC is higher than the recommended figure.
Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation
Check the condition of the air filterCheck the condition and seal of the air supply circuitContinue to Step 1Circuit component damagedReplace the filter element Op.   1048A14 
Circuit component damagedReplace the component (see Assembly 1048A)
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socketCheck that there are no fault in the engine management control unitContinue to Step 2An error is detected in the control unitContinue according to the instructions for the diagnostic equipment
Lack of dialogue with the control unitRestore the connection between the engine management control unit and the diagnostic connector ( See   E5030  PETROL ENGINE ELECTRONIC MANAGEMENT ).
2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Using the diagnostic equipment (Examiner or other instruments) carry out the active diagnosis of:

  • vapour recovery solenoid valve
  • electro-injector
Continue to Step 3Connections faultyRestore the connection for the solenoid valve and the injectors with the control unit ( See   E5030  PETROL ENGINE ELECTRONIC MANAGEMENT ).
Solenoid valve faulty Replace the vapour recovery soleniod valve Op. 1080E28
Injectors faultyReplace the injectors Op.   1056B70 
3LAMBDA SENSOR CHECKAll OKProblems metOperation
Check that the Lambda sensor is working properlyContinue to Step 4Lambda sensor not working properlyReplace the Lambda sensor Op.   1080B60 
4CATALYTIC CONVERTER CHECKAll OKProblems metOperation
Check that the catalytic converter is working properlyContinue to Step 5Catalytic converter not working properlyReplace the catalytic converter Op.   1080B62 
5FUEL PRESSURE CHECKAll OKProblems metOperation
Check the fuel supply pressure Op.   0510C10  Continue to Step 6Pressure not correctReplace the fuel pump assembly Op.   1040A70 
6CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'