2888490 - W10 BLACK EXHAUST FUMES
There are a great deal of exhaust fumes, with dark coloured smoke;| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation | 
|---|---|---|---|---|
| Check whether the problem is connected with oil consumption | Continue to Step 1 | Excessive oil consumption | See table X05 | |
| 1 | AIR CIRCUIT CHECK | All OK | Problems met | Operation | 
| Check: 
 | Continue to Step 2 | Circuit component damaged | Replace the component (see Assembly 1048A) | |
| 2 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socketCheck that there are no fault in the engine management control unit | Continue to Step 3 | An error is detected in the control unit | Continue according to the instructions for the diagnostic equipment | |
| Lack of dialogue with the control unit | Restore the connection between the engine management control unit and the diagnostic connector ( See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT ). | |||
| 3 | ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Using the diagnostic equipment (Examiner or other iinstruments) carry out the active diagnosis of the iinjectors. | Continue to Step 4 | Injector connections faulty | Restore the connection of the injectors with the control unit, ( See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT ) | |
| Injectors faulty | Replace the injectors Op. 1056B70 | |||
| 4 | FUEL PRESSURE CHECK | All OK | Problems met | Operation | 
| Check the fuel supply pressure Op. 0510C10 | Continue to Step 5 | Pressure not correct | Replace the fuel pump assembly Op. 1040A70 | |
| 5 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | Fault persists | Search for the fault starting from another symptom' | |