2891469 - 1042A50 PIPE (1) CONNECTING CNG RECHARGING SYSTEM SOLENOIDS - R R (BIPOWER, BLUPOWER)

Removing ( Refitting ) Position the vehicle on a lift.Proceed with draining the high pressure circuit following the instructions in the specific operation    Op. 1042A02 C.N.G. - FUEL SYSTEM SAFETY CHECKRaise the lift. 1. Undo the connectors from the valve assemblies.2. Remove the connecting and repressurizing pipe (2a) or (2b).
Refitting ( Removing ) Check the condition of the solenoid valve connecting pipe removed.Fit the pipe on the two valves.Tighten the two pipe connectors.
FasteningComponentØ  Value(daNm)
--CNG RECHARGING PIPE CONNECTIONM102.5
Move the CNG cut-off solenoids to open position by hand and check system is efficient.Connect the Examiner diagnostic equipment in the "Active Diagnosis" ambient, select and carry out "Gas solenoid valve relay" item in order to allow the opening of the solenoid valves and the renewal of the CNG system operating pressure; read the pressure value on the sensor located on the pressure reduction unit in the engine compartment which should be greater than or equal to 14 bar, otherwise it will not be possible to switch from petrol to methane.    Op. 1042A06 C.N.G. - FUEL SYSTEM CHECK FOR ANY LEAKS USING ELECTRONIC DETECTOR FOLLOWING OPERATIONSRemove the vehicle from the lift.