2892612 - E5010 STARTING AND RECHARING - Functional description (GPOWER, Euro 3, BIPOWER, BLUPOWER)
Functional description
When the ignition key for the switch
H1
is turned to the extreme position (AVV) [START], the solenoid winding
(pin 50) of the starter motor
A20
is supplied.
This supply comes from the battery via the
line of maxifuse IGN of
B5
.
Pin 30 of
A20
, the actual starter
motor, receives the voltage coming directly from the battery
A1
.
The direct current generated by the alternator
A10
(pin B+) is sent to the battery
A1
through motor
A20
. When the alternator is not turning, i.e. not recharging
the battery, an earth signal is sent from pin D+ to instrument
panel
E50
- pin 8 of connector B.
The instrument
E50
is supplied with
the ignition switched on (INT) at pin 19 of connector A from the
line protected by fuse
F1
of the junction unit
B1
:
when this signal arrives, the 'recharging' warning light comes on.
When the engine has been started up, this
signal becomes 12 V and the warning light therefore goes out.