2891498 - 1043A54 cover of gpl tank valve unit with submerged fuel pump ecu r r with gpl tank removed (GPOWER)

Removing ( Refitting ) 1. Undo the fixing bolt (1a) and place the cover with the control unit (1b) incorporated to the side.
1. Disconnect the electrical connector for the LPG electric pump management control unit.

NameConnector
1Availability. of electric pump and GPL supply. solenoid valve.  M17 
2. Undo the bolt (2a) and disconnect the electrical connector for the pump (2b), then remove the cover for the valve unit with the electronic control unit.
Refitting ( Removing ) Connect the electrical connector for the pump, taking special care to fit it correctly on the three contacts on the LPG pump; secure the connector using the bolt.Connect the electrical connector for the electric pump management control unit.

NameConnector
-Availability. of electric pump and GPL supply. solenoid valve.  M17 
Fit the cover with the control unit incorporated and tighten the fixing bolt.
Check the hermetic seal between the cover and the housing on the canister. All the comopnents inside must be positioned in an orderly manner.