186007245 - 1042A74 RIGHT CYLINDER OF CNG CYLINDER UNIT R R (BIPOWER)

Removing ( Refitting ) Position the vehicle on a lift.Proceed with draining the high pressure circuit following the instructions in the specific operation    Op. 1042A02 C.N.G. - FUEL SYSTEM SAFETY CHECK    Op. 1042E60 CNG CYLINDER UNIT PROTECTION SEAL - R R
Before disconnecting the right side cylinder, mark its exact position in relation to the body, the retaining collars and the central cylinder.
1. Disconnect the connector of the pipe connected to the central cylinder on the right side cylinder solenoid.2. Disconnect the connector of the pipe connected to the left side cylinder on the right side cylinder solenoid.3. Disconnect the electrical connection of the methane cut-off solenoid on the right side cylinder.
DescriptionConnector
Methane supply solenoid    See L60 METHANE SUPPLY SOLENOID
Arrange the cylinder support tool on a hydraulic column lift able to take the weight of the cylinder.
DescriptionCode
Support for CNG cylinders1.870.732.000
1. Position the tool for supporting the cylinder during the removal operation beneath the right side cylinder.
DescriptionCode
Support for CNG cylinders1.870.732.000
2. Undo retaining nuts (2a), recover the retaining bushes and springs (2b) on the inner part of the cylinder retaining collars.3. Undo bolts (3a) on the outer side and withdraw the cylinder support collars (3b).4. Lower the hydraulic lift and remove the right side cylinder from its seat on the body.With the aid of a second operator, remove the cylinder from the support tool and arrange on suitable stands.
It is absolutely forbidden to remove the solenoid assembly from the CNG cylinders. In the case of solenoid failure, it is only possible to perform the dismantle/rebuild procedure.
    Op. 1042A20 INJECTION SYSTEM SOLENOID ON CYLINDER R R
In the case of methane cylinders that require servicing every 5 years, connect the relevant certified CUNA centres (only for Italy), which will supply a new set of overhauled cylinders complete with solenoids, inspection certificate and new plates showing the expiry date. In Italy, a list of service centres has been distributed to the Service Network in a specific publication entited "3/5-yearly fuel system servicing and inspection"
Refitting ( Removing ) With the aid of a second operator, position the cylinder on the support tool.
DescriptionCode
Support for CNG cylinders1.870.732.000
Raise the tool and position the cylinder in its underbody housing compartment.Position the retaining collars and fit the bolts on the outer side, springs, bushes and nuts on the inner side.Tighten the bolts on the outer side securing the cylinder support collars to torque.Tighten the nuts on the inner side securing the cylinder support collars to torque.Remove the cylinder support tool.Connect the connector of the pipe connected to the central cylinder on the right side cylinder single-acting valve.Connect the connector of the pipe connected to the left side cylinder on the right side cylinder single-acting valve.Connect the electrical connection of the methane cut-off solenoid on the right side cylinder.
DescriptionConnector
Methane supply solenoid    See L60 METHANE SUPPLY SOLENOID
Move the CNG cut-off solenoids to open position by hand and check system is efficient.Connect the Examiner diagnostic equipment in the "Active Diagnosis" ambient, select and carry out "Gas solenoid valve relay" item in order to allow the opening of the solenoid valves and the renewal of the CNG system operating pressure; read the pressure value on the sensor located on the pressure reduction unit in the engine compartment which should be greater than or equal to 14 bar, otherwise it will not be possible to switch from petrol to methane.    Op. 1042A06 C.N.G. - FUEL SYSTEM CHECK FOR ANY LEAKS USING ELECTRONIC DETECTOR FOLLOWING OPERATIONS    Op. 1042E60 CNG CYLINDER UNIT PROTECTION SEAL - R R