2891805 - 5040A14 air conditioner cooling circuit - check and repair any leaks by tightening fittings
Follow the safety instructions ( See assembly 5040A air conditioner coolant circuit ). |
Introduce a certain amount
of R134a coolant fluid (around 200 g) into the system.Use a leak detector to identify the area
where the leak is coming from.Drain the fluid and eliminate the leak,
tightening any slack connectors or replacing any damaged pipes or components.
Repressurize using coolant fluid (
Refer to
op.. 5040A10 Air
conditioning refrigerant CIRCUIT - Draining and Refilling
).