2892543 - E3046 BOOT OPENING - Functional description

Functional description

The integrated services control unit M40 manages the operation of the circuit. The control unit M40 is supplied directly by the battery - in 8 of connector B - from the line for maxifuse J/B2 of B5 via fuse B19 . Pin 13 of connector B provides the earth. An earth signal is sent to the control unit M40 , at pin 17 of connector B by operating the special control H71 . The control H71 is illuminated when the ignition is on INT - pin 2 from the line protected by the bridge fuse B26. Similarly, the switch I33 is activated via the key and an earth signal is sent to the control unit M40 at pin 14 of connector B. The latter sends a signal - pin 19 of connector A - which energizes the boot opening relay J56 which supplies the boot locking geared motor N57 via the line protected by bridge fuse F19. The speedometer signal from the instrument panel E50 reaches pin 14 of connector A of M40 . A boot open signal reaches pin 17 of connector A of M40 which inhibits the unlocking.