2891804 - 5040A10 Air conditioning refrigerant CIRCUIT - Draining and Refilling

Follow the safety instructions (  See assembly 5040A   air conditioner coolant circuit ).
1. Use the special Cleaner 134 draining/repressurizing equipment.
Let the engine run with the air conditioning switched on for 10 - 15 minutes.1. Undo the repressurizing valve plugs.2. Before attaching the connectors to the needle valves, move the knurled ring nut upwards.
For improved safety, the rapid attachment connectors for the equipment connection pipes have different diameters: the one for the low pressure side is larger and the one for the high pressure side is smaller.
3. Connect the high pressure connecting pipe (HIGH) to the corresponding rapid attachment valve.4. Connect the low pressure connecting pipe (LOW) to the corresponding rapid attachment valve.
Start the procedure for draining the coolant fluid, following the instructions in the equipment manual.1. Whilst draining the system, the fluid removed from the compressor should be collected in a special container.
The fluid is extremely hygroscopic: avoid leaving the containers open.
Ripristinare nell'impianto la stessa quantità di olio indicata nel contenitore.

TypeComponentNameQty.
-OilAir conditioner compressorPAG SP 20-

If certain components are replaced, the following quantities of fluid must be added for each of the components replaced:

  • Drier filter, 15 cm3
  • Pipes, 5 cm3 /m
  • Evaporator, 40 cm3
  • Condenser, 40 cm3
In the case of accidental breakages which result in the rapid draining of the system (in less than 5 minutes), it is not possible to determine the exact amount of fluid which has escaped because of the high pressure of the fluid. Add 50 cm 3 of fluidStart the coolant fluid repressuring procedure, following the instructions in the equipment manual.Introduce the recommended quantity of coolant fluid.

TypeComponentNameQty.
-Coolant fluid [kg]Air conditioning circuitR134a0.650
In the case of damage to the compressor or other system components followed prolonged exposure to the air of the pipes (more than 6 hours), the system "WASHING" procedure has to be carried out, proceeding as follows.Clean the pipes connected to the compressor using an air line.Connect the (now drained) system to the repressurizing equipment.Introduce the recommended quantity of coolant fluid at the high pressure side.Recover the coolant fluid from the low pressure side.Repeat the introduction and recover the fluid.Proceed with the system draining and repressurizing operations as described previously.
If the system is being washed, the entire amount of fluid in the system is eliminated.
Refill the system with the recommended amount of fluid.

TypeComponentNameQty.
-Oil (cm3)Air conditioner compressorPAG SP 20130