2892537 - E3040 CENTRAL LOCKING - Functional description (Right hand drive)
Functional description
The M80 central locking control unit controls the operation of the circuit. The M80 control unit (pin +) is supplied directly by the battery via the line protected by the special fuse B19 ; pin (-) provides the reference earth.Control unit M80 receives input signals coming from locks N50 and N51:
- for locking, if the earth signal goes from pin 2 to pin 3 of M80 ;
- for unlocking, if the earth signal goes from pin 3 to pin 2 of M80 .
In accordance with the logic illustrated previously, control unit M80 simultaneously controls the two front locks N50 and N51 and the rear locks N55 and N56 from pins 1M and 2M:
- locking signal; 12V from pin 2M and earth to pin 1M
- unlocking signal: 12V from pin 1M and earth to pin 1M