2891492 - 1043A06 gpl tank complete with submerged fuel tank and valve unit r r (GPOWER)
 Removing
		(
		Refitting
Removing
		(
		Refitting )
	
                                          Drain the section of the pipe from the
recharging filler to the tank and the LPG supply and return pipes
from the tank to the pressure regulator, following the procedure
and the reguations descibed 
                                           - 1043A02  lpg system lines pipe draining operations
                                           .
                                       Return the vehicle to the workshop and
place it on a lift. Disconnect the battery negative terminal. - 1043E12  gpl tank guard protection r r
                                           .
                                       1. Disconnect the electrical connectors for the pump management
device (1a) and the LPG level sensor (1b).
		)
	
                                          Drain the section of the pipe from the
recharging filler to the tank and the LPG supply and return pipes
from the tank to the pressure regulator, following the procedure
and the reguations descibed 
                                           - 1043A02  lpg system lines pipe draining operations
                                           .
                                       Return the vehicle to the workshop and
place it on a lift. Disconnect the battery negative terminal. - 1043E12  gpl tank guard protection r r
                                           .
                                       1. Disconnect the electrical connectors for the pump management
device (1a) and the LPG level sensor (1b).|  | Name | Connector | 
|---|---|---|
| 1a | Availability. of electric pump and GPL supply. solenoid valve. | M17 | 
|  | Name | Connector | 
|---|---|---|
| 1b | GPL level sensor | K33 | 


|  | Name | Country | 
|---|---|---|
| 1 | Support for CNG canisters | 1.870.732.000 | 
|  | Name | Country | 
|---|---|---|
| - | GPL twin canister support | 1.870.833.000 | 
|  | Before removing the canister, mark its position in relation to the securing collar to facilitate the refitting and ensure that the canister is correctly positioned. | 

|  | The canister should be moved and positioned on supports so that the pump cover is always facing upwards, in relation to the position it is fitted on the vehicle. Do not turn it upsidedown: the oil in the pump could come out and impair pump operation. With this in mind, position two wooden blocks at the sides of the tank to prevent it from turning over. | 
|  | Once removed, the canister should be placed in the open in a secure place which is sheltered from the elements. Place a card on the canister containing the following warnings: Do not touch - Do not turn upsidedown - No naked flames - No smoking - Do not use electrical equipment or incandescent lamps. | 
|  | In the case of operations on the components directly in contact with the tank such as: 80% valve, electric pump, solenoid valve, float, the tank should be sent to the specialist service centres for draining and incapacitating after agreement with T.D.A. (Italy)/Teseo (abroad). . | 
 Refitting
		(
		Removing
Refitting
		(
		Removing )
	Take the canister and position it on the
supporting tool.
		)
	Take the canister and position it on the
supporting tool.|  | Name | Country | 
|---|---|---|
| - | Support for CNG canisters | 1.870.732.000 | 
|  | Name | Country | 
|---|---|---|
| - | GPL twin canister support | 1.870.833.000 | 
|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| - | Bolt | LPG TANK FASTENERS | M8 | 2.5 | 
|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| - | Nut | LPG TANK FASTENERS | M10 | 1.5 | 
|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| - | Pin | LPG TANK FASTENERS | M12 | 6 | 
|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| - | Connector | L.P/G SUPPLY.RETURN PIPE CONNECTOR.. | - | (supply) 1.4 | 
|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| - | Connector | L.P/G SUPPLY.RETURN PIPE CONNECTOR.. | - | (return) 1.6 | 
|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| - | Connection | PIPE FROM FILLER TO LPG TANK | 1/4 GAS | (tank) 1.6 | 
|  | Name | Connector | 
|---|---|---|
| - | Availability. of electric pump and GPL supply. solenoid valve. | M17 | 
|  | Name | Connector | 
|---|---|---|
| - | GPL level sensor | K33 | 
|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| - | Niplo | LPG DELIVERY PIPE FROM CONNECTOR TO REGULATOR. | M10 x 1 | (regulator) 1 | 
|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| - | Niplo | LPG RETURN PIPE FROM CONNECTOR TO REGULATOR. | M10 x 1 | (regulator) 1 |