2888312 - A01 ALARM DOES NOT COME ON
When operating the alarm with the remote control:
- the LED does not flash,
- the doors do not open/close
- the lights do not flash
- the siren does not emit auditory signals
|  | The alarm only can only be switched on with the ignition key in the OFF or PARK positions or with it extracted. | 
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation | 
|---|---|---|---|---|
| WARNING:
the auditory signals and the flashing of the direction indicators
are either activated or not, according to the various country modes  see DESCRIPTION AND OPERATION: 5580E anti-theft device Preliminarily check: 
 | Continue to Step 1 | Remote control battery run down | Replace battery | |
| Key not correct | Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socketProgramme keys correctly. | |||
| 1 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Connect
the diagnostic equipment (Examiner or other instruments) to the
diagnostic socket Check, in order: 
 | Continue to Step 2 | Error detected in the control unit or receiver | Continue according to the instructions for the diagnostic equipment | |
| Dialogue failure for diagnostic equipment between the control unit and the receiver | Restore the connection between the control unit and the diagnostic connector ( See E7015 ALARM ). | |||
| 2 | CHECK CONTROL UNIT OPERATION | All OK | Problems met | Operation | 
| It is also possible to carry out the fault diagnosis of the system by observing the behaviour of the LED when switching on and off: or, by carrying out a manual fault diagnosis of the system ( see DESCRIPTION AND OPERATION: 5580E anti-theft device). | Continue to Step 3 | An error is detected in the control unit | Restore the faulty components Check and, if necessary, replace the alarm control unit. Op. 5580E46 | |
| 3 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present. | End of diagnosis | Fault persists | Search for the fault starting from another symptom' | |