|  |  | Results of the tests | 
| 1 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
|---|
|  | Connect
the diagnostic equipment (Examiner or other instruments) to the
diagnostic socket Check: there are no faults in the air bag control unitplausibility of all the parameters
 | Continue to Step 2 | An error is detected in
the control unit | Continue according to the instructions for the diagnostic
equipment | 
| Lack of dialogue with the control unit | Restore the connection between Air Bag control unit and
diagnostic connector ( See   E7030  AIRBAG ) | 
| 2 | CHECK INSTRUMENT POWER SUPPLY | All OK | Problems met | Operation | 
|---|
|  | Check the connection betwen air bag control unit and instrument
( See   E7030  AIRBAG ).|  | The air bag warning light is fitted
with an interior circuit that monitors the connection between warning
light and control unit. | 
 | Continue to Step 3 | Connections not correct | Restore the connections | 
| Instrument not working | Change the instrument Op.   5560B10 | 
| 3 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation | 
|---|
|  | Check
that the fault is no longer present | End of diagnosis | Fault persists | Search for the
fault starting from another symptom' |