2891809 - 5040A50 pipe from compressor to air conditioner condenser - r+r
|  | Follow the safety instructions ( See assembly 5040A air conditioner coolant circuit ). | 
 Removing
		(
		Refitting
Removing
		(
		Refitting )
	 - 5550B30  l/h or r/h horn (one)
- r+r
                                          Drain the coolant fluid (refer to op. 
                                            5040A10  Air conditioning refrigerant CIRCUIT - Draining and Refilling
                                           ).
                                       1. Undo the bolts and the nut.2. Disconnect the pipe connectors.
		)
	 - 5550B30  l/h or r/h horn (one)
- r+r
                                          Drain the coolant fluid (refer to op. 
                                            5040A10  Air conditioning refrigerant CIRCUIT - Draining and Refilling
                                           ).
                                       1. Undo the bolts and the nut.2. Disconnect the pipe connectors.|  | Seal the disconnected connectors, using suitable plugs, to prevent humidity and impurities from entering the system. | 

 Refitting
		(
		Removing
Refitting
		(
		Removing )
	Check that the pipe is not
damaged or cracked.Reposition the pipe and fix it using the
retaining bands.
		)
	Check that the pipe is not
damaged or cracked.Reposition the pipe and fix it using the
retaining bands.|  | Replace the O-rings for the connectors. Only use green coloured seals, resistant to R134A coolant fluid. Lubricate the thread of the connectors using anti-freeze. | 
|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| - | Bolt | COOLANT SYSTEM FITTINGS | M6 | 0.9 | 
|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| - | Bolt | Compressor pipe connector | M10 x 1.25 | 3.5 |