2892635 - E6020 AIR CONDITIONING - Functional description (Air Conditioner)
Functional description
The relay
J35 controls the passenger
compartment air fan circuit
The supply for the relay contact arrives
from the battery through the line for the maxifuse J/B1 of
B5 protected by fuse F12 for the junction unit B1, whilst the energizing of the coil is controlled by
the ignition (INT/A) through the line protected by fuse B27.
The relay
J35 supplies the control
knob H81: this controls the fan at the different
speeds via the regulator O30.
The voltage signal varies according to the
position of the knob and through the resistance of the regulator
O30 determining four different voltage signals for the fan N85 which sends outside or recirculation air to he duct/distributor
unit at 4 different speeds.
The outside/recirculation air intake flap
motor
N82 is operated by a special button, located in
the control panel H80: the operation of the button
sends an earth signal and a supply controlled by the ignition (INT/A)
protected by fuse B27 which are reversed to reverse
the direction of rotation of the motor.
The control panel has ideograms which are
lit up, when the side lights are on, by lights
G45, supplied
by the line protected by fuse F3 for the junction
unit B1
(
See
E2010
SIDE LIGHTS / NO. PLATE
LIGHTS
).