2892617 - E5020 ENGINE COOLING - Functional description (Euro 3)

Functional description

The supply for the fan N11 arrives directly from the battery from the line for the maxifuse B8 : the fan therefore operates when it receives an earth command. The relays J30 and J31 have coils supplied by the line for maxifuse UGD of B5 protected by fuse B35. They are energized by an earth signal coming from the engine control unit M10 . if the coolant temperature reaches the first temperature stage, or the 4-stage pressure switch K10 - pin 3 - indicates to control unit M10 - pin 52 of connector A - that the first pressure stage has been reached, control unit M10 sends a signal to 1st speed relay R7 from pin 20 of connector A. The relay then sends an earth signal which, via the additional resistance O10 , operates the fan N11 which rotates at the first (slow) speed. If the engine coolant reaches a higher temperature level or the 4 stage pressure switch K10 (pin 1) signals to the control unit M10 (pin 51 of connector A) that a high pressure stage has been reached, then the control unit M10 sends an earth signal (from pin 19 of connector A) to the 2nd speed fan relay J31 which energizes the coil. The relay then sends an earth signal directly to the fan N11 which rotates at the maximum speed.