3024831 - 1056B09 hot film air flow meter (debimeter) r + r

Removing ( Refitting ) Ensure that the ignition key is in the OFF postition, then disconnect the battery negative terminal.

NameConnector
-Battery  A1B 
1. Disconnect the electrical connection from the air flow meter.

NameConnector
1Air flow meter  K41 
2. Loosen collars (2a) and remove air flow meter (2b) after disconnecting it from the air intake sleeves.
Refitting ( Removing ) Refit the air flow meter, connect to the air intake sleeves and secure with collars.Connect the electrical connection to the air flow meter.Connect the battery terminal (-).