3025453 - 5040D88 control motor of any flap - r r with air conditioner casing removed

Removing ( Refitting ) 1. Unscrew the motor retaining bolt.2. Disconnect the electrical connections for the motor (2a, 2b, 2c, 2d).

NameConnector
2aLeft air mixture flap actuator  N78 

NameConnector
2bAir distribution actuator  N80 

NameConnector
2cRight air mixture flap actuator  N79 

NameConnector
2dAir intake actuator  N82 
3. Remove the motor (3a) releasing its connection (3b).
Refitting ( Removing ) Check that the motor is undamaged.Position the motor attaching its connection.Tighten the bolts fixing the motor.Connect the motor electrical connections.