3025540 - 5530B52 Battery DRIP TRAY/SUPPORT - R.R.

Removing ( Refitting ) Proceed with removal  - 5530B10  battery - r+r .1. Remove the relay/fuse box cover.2. Undo the nut (2a) and disconnect the earth lead (2b) from the relay-fuse box.

NameConnector
2bEngine compartment junction unit  B1X 
1. Turn the relay-fuse box upwards.2. Disconnect the electrical connections (2a), (2b), (2c), (2d) and (2e) from the relay-fuse box.

NameConnector
2aEngine compartment junction unit  B1A 

NameConnector
2bEngine compartment junction unit  B1C 

NameConnector
2cEngine compartment junction unit  B1E 

NameConnector
2dEngine compartment junction unit  B1D 

NameConnector
2eEngine compartment junction unit  B1B 
1. Release the relay-fuse box from the hinges and remove it.
1. Undo the nut (1a) and disconnect the earth lead (1b) from the battery terminal (-).

NameConnector
1bBattery  A1B 
2. Lift up the wiring protection (2a), as necessary, then release the earth lead (2b), disconnected previously, from the relay-fuse box casing.
1. Undo the nut (1a) and remove the relay-fuse box casing (1b).2. Undo the nuts (2a) and remove the relay-fuse box support (2b).
Release the electrical wiring from the fastenings on the battery drip tray.
On the Selespeed version, the electrical connection for the gear selection hydraulic unit must be released from the battery drip tray.
1. Undo the nut fixing the air filter to the battery drip tray.2. Undo the bolts securing the battery cradle to the body.3. Remove the battery cage.
Refitting ( Removing ) Place the battery drip tray back in its housing and secure it to the bodyshell using the bolts.Tighten the nuts fixing the air filter to the battery drip tray.Secure the electrical wiring using the bands on the battery drip tray.Place the relay-fuse box mounting back in its housing and secure it using the nuts.Place the casing for the relay-fuse box back in its housing and secure it using the nut.Place the earth lead in its housing through the opening in the relay-fuse box casing and connect it to the battery terminal (-).Place the relay-fuse box back in its housing and secure it to the hinges.Connect the electrical connections to the relay-fuse box.Rotate the relay-fuse box in its housing.Connect the earth lead to the relay-fuse box.Place the relay/fuse box cover back in its housing.Proceed with refitting  - 5530B10  battery - r+r .