3024721 - 0010T20 coolant change

Position the vehicle on the ramp.Undo the engine coolant reservoir cap. Proceed with removal  Refer to op.. 7055B54  under-engine guard - r r . 1. Disconnect the lower coolant outlet hose from the radiator and drain the engine coolant.
Manually press the springs and remove the rapid attachment for the hose.
Recover the coolant using a suitable container.
1. Disconnect the coolant return pipe to the engine coolant reservoir, reservoir side.Blow compressed air into the disconnected pipe to empty the pipe fully.Connect the pipe.
1. Open the bleed (1a) located on the radiator and/or bleed (1b) located on the heater's inlet hose.
Connect the lower coolant outlet hose from the radiator.Proceed with refitting  Refer to op.. 7055B54  under-engine guard - r r . Remove the car from the ramps. Fill the system by slowly pouring the specified coolant into the engine coolant reservoir, without exceeding the MAX mark on the reservoir.

TypeComponentNameQty.
-Fluid [l]ENGINE COOLING CIRCUITMixture of 50% Paraflu 11 for Alfa Romeo/distilled water7.2
Close the bleed on the radiator as soon as liquid starts to spill out.Continue filling until liquid emerges from the bleed on the heater's inlet hose, then tighten the bleed.Finish filling until the MAX level on the engine coolant reservoir is reached.Start the engine and run it at idle speed for 2 or 3 minutes.If necessary top up the engine coolant reservoir up to the MAX level.Refit the engine coolant reservoir cap.Accelerate periodically and gradually up to about 4000 rpm.If the fluid in the engine coolant reservoir reaches the MIN mark, undo the cap very carefully and top up to the MAX level, then retighten the cap.Wait until the fan has activated a t least a couple of times.Stop the engine and wait for the fluid to cool down.If necessary, unscrew the reservoir cap and top up to the MAX level.