3024759 - 1008C10 power unit upper reaction link r r

Removing ( Refitting ) 1. Release the fuel vapour recirculation pipe from the fastening on the power steering fluid reservoir.2. Disconnect the rapid attachments and remove the fuel vapour recovery pipe.
Seal the fuel vapour recovery system pipes.
1. Undo the bolts (1a) and (1b), then remove the power unit reaction rod (1c).
Refitting ( Removing ) Place the power unit reaction rod back in its housing and fix it tightening the bolts to the recommended torque.

FasteningComponentØValue(daNm)
-BoltREACTION RODM10(Bracket on engine/bracket on bodyshell side) 4.5 ÷ 5.5

FasteningComponentØValue(daNm)
-BoltREACTION RODM10(Bracket on engine/bracket on bodyshell side) 4.5 ÷ 5.5
Place the fuel vapour recovery pipe back in its housing and connect the rapid attachments.Fix the fue vapour recirculation pipe with the band on the power steering fluid reservoir.