3026207 - E5010 STARTING AND RECHARING - Functional description (Cambio robotizzato)

Functional description

When the ignition key in the switch H1 is turned to the extreme position (START) - pin 50 - the winding of the solenoid - pin 50 - of the starter motor A20 is supplied. This supply comes from the battery via the line of maxifuse IGN of B5 . However, this supply only occurs in the presence of an enablement signal - from pin 42 of connector A of the SELESPEED control unit M54 (while pin 76 of connector B of M54 receives the starting request signal); The starting enablement relay J05, with a supply controlled by the ignition (15/54) from the line protected by fuse F11 of the engine compartment junction unit B1A, sends a power supply to pin 50 of the starter motor A20; The supply controlled by the ignition (15/54) reaches pin 28 of connector A of M54 .  See E7051  ROBOTIZED GEARBOX . Pin 30 of A20 , the actual starter motor, receives the voltage coming directly from the battery A1 . The direct current generated by the alternator A10 (pin B+) is sent to the battery A1 , passing through the motor A20 . When the alternator does not turn, and so does not recharge the battery, an earth signal is sent from pin D+ to the Body Computer - pin 19 of connector A: this is connected via the CAN line to the instrument panel E50 and manages, as described above, the switching on of the recharging warning light on the instrument panel E50 .