3022558 - A05 ALARM LED NOT WORKING

When the alarm is operated, the LED does not come on
Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment (Examiner) and check whether there are any faults in the systemContinue to Step 2-
2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the diagnostic equipment, carry out the active diagnosis of the LEDContinue to Step 4LED does not come onContinue to Step 3
3WIRING CHECKAll OKProblems metOperation
Check the continuity and insulation of the wiring between the Body Computer and the panelCheck that the supply reaches the LED from the Body Computer See   E7015  ALARM Continue to Step 4The supply does not leave the Body Computer for the LEDReplace the Body Computer Op.   5505A32 
The supply is sent correctly from the Body Computer but the LED does not come onReplace the LED in the panel Op.   5505A24 
4CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentFault persistsSearch for the fault starting from another symptom'