3022561 - A25 ALARM VOLUMETRIC SURVEILLANCE NOT WORKING

When the alarm is activated, the volumetric surveillance does not work
Results of the tests
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Volumetric surveillance can be excluded voluntarily from the operation of the system: wiring diagram See   E7015  ALARM
Connect the diagnostic equipment (Examiner or SDC) to the diagnostic socket and check whether there are faults in the CAN network
Continue to Step 2Faults present on the CAN networkRepair the connections on the interested nodes
2CHECK VOLUMETRIC SENSORSAll OKProblems metOperation

Check, in order:

  • Operation of volumetric sensors
  • Connections between sensors and Body Computer: wiring diagram See   E7015  ALARM
Continue to Step 3Sensor faultyReplace sensors Op.   5580E22 
Connections brokenRenew the connections: wiring diagram See   E7015  ALARM
3CORRECT OPERATION CHECKAll OKProblems metOperation
Check that the fault is no longer presentFault persistsSearch for the fault starting from another symptom'