3022651 - K10 DOORS OPEN CHECK NOT WORKING

When one of the doors is opened, this is not displayed by the special warning light/icon in the instrument panel. When the doors are opened, the interior lights work properly.
Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect an Examiner to the diagnostic socket

Verify:

  • that there are no faults in the Body Computer;
Continue to Step 2There are faults in the Body ComputerProceed in accordance with the instructions provided by the instrument
2CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Keeping the Examiner connected to the diagnostic socket.

Verify:

  • that there are no faults in the instrument panel
Continue to Step 3There are faults in the instrument panelProceed in accordance with the instructions provided by the instrument
3CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Keeping the Examiner connected to the diagnostic socketCarry out the active diagnosis of the warning lightsContinue to Step 4Warning light not workingDisplay/instrument panel defective Replace the instrument panel Op.   5560B11 
4CHECKING ELECTRICAL EQUIPMENTAll OKProblems metOperation

Check connections between:

  • Body Computer and switches in locks
Continue to Step 5Connections not correctRestore the correct connections : See   E4010  INSTRUMENT PANEL
5SWITCH CHECKAll OKProblems metOperation
Check the operation of the switches in the locksContinue to Step 6Lock with switch defectiveReplace the lock Op.   7005N21 
6CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentFaulty Body ComputerReplace the Body Computer Op.   5505A32  Search for the fault starting from another symptom'