3022683 - N01 CIGAR LIGHTER/CURRENT SOCKET NOT WORKING

When the cigar lighter is pressed or a consumer connected to the special connection, the cigar lighter / current socket does not work.
The power sockets all have a heat protection device: if devices with high energy absorption are connected, this protection cuts off the supply.
Results of the tests
1CIGAR LIGHTER CHECKAll OKProblems metOperation
Check the cigar lighter/current socket: in particular, make sure that the thermal protection device inside the socket has not been affected due to overloadingContinue to Step 2Thermal protection affectedReplace the cigar lighter/current socket Op.   7065C72 
2CIGAR LIGHTER ELECTRICAL CIRCUIT CHECKAll OKProblems metOperation

Check, in order:

  • Cigar lighter fuse (in dashboard control unit)
  • Relay (in dashboard control unit)
  • Cigar lighter earth
  • Continuity and insulation of cigar lighter electrical circuit : See   E3070  CIGAR LIGHTER / CURRENT SOCKET
Continue to Step 3Component defectiveReplace the component (if a fuse is involved, search for the cause of the problem)
Connections not correctRestore the connections : See   E3070  CIGAR LIGHTER / CURRENT SOCKET
3CORRECT OPERATION CHECKAll OKProblems metOperation
Check that the fault is no longer presentFault persistsSearch for the fault starting from another symptom'