3022691 - N36 THE NAVIGATOR IS NOT WORKING

the navigator is incorporated in the Connect.
Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation
Check that the NAV CD is correctly insertd and recognized by the Connect.Continue to Step 1NAV CD not inserted Insert the NAV CD
NAV CD not inserted Replace the NAV CD
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the Examiner diagnostic equipment to the diagnostic connector and check that there are no faults at the Connect Node in the errors ambient Continue to Step 2Presence of faults Continue following the instructions for the diagnostic equipment.
2CHECKING ELECTRICAL EQUIPMENTAll OKProblems metOperation
Remove the Connect and check that the aerial connector is correctly inserted in its housing. See   E4091  CONNECT Continue to Step 3Connector disconnected from the Connect.Insert the connector in its housing
3CHECKING ELECTRICAL EQUIPMENTAll OKProblems metOperation
Check the continuity/insulation of the connecting cable between the Connect and the G.P.S. aerial See   E4091  CONNECT Continue to Step 4Aerial lead faultyRenew the electrical connections See   E4091  CONNECT
4CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsReplace the aerial support.