3022694 - N71 CONNECT DOES NOT RECEIVE VOICE MESSAGES

The 'voice command' function is managed by the telephone module which is incorporated in the Connect. The microphone is located on the outside.
Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation
Check that the Connect settings disable the voice command function.Continue to Step 1Settings not correct.Restore the correct values.
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the Examiner diagnostic equipment to the diagnostic connector and check the following at the Connect Node.

In errors ambient

  • that there are no faults
Continue to Step 2Presence of faults Continue following the instructions for the diagnostic equipment.
2CHECKING ELECTRICAL EQUIPMENTAll OKProblems metOperation
Remove the Connect and check the continuity/insulation of the cable connecting the Connect and the microphone in the courtesy light. See   E3570  INTEGRATED RADIO PHONE Continue to Step 3Microphone wiring faultyRenew the electrical connection.
3MICROPHONE IMPEDANCE CHECKAll OKProblems metOperation
Check the continuity/insulation of the microphone in the courtesy light. See   E3570  INTEGRATED RADIO PHONE Continue to Step 4Microphone faultyMicrophone faulty
4CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsReplace the Connect module.