3024759 - 1008C10 power unit upper reaction link r r

Removing ( Refitting ) 1. Undo the bolts (1a) and remove the power unit reaction rod (1b).
Refitting ( Removing ) Place the power unit reaction rod (1a) back in its housing and fix it tightening the bolts to the recommended torque.

FasteningComponentØValue(daNm)
-BoltREACTION RODM104.5 ÷ 5.5