3024974 - 1056B10 air flow meter - r + r

Removing ( Refitting ) Ensure that the ignition key is in the OFF position, then disconnect the negative battery terminal (-).

NameConnector
-Battery  A1B 
Proceed with removal  - 1048A28  vacuum air circuit resonator pipe - r+r . 1. Disconnect the electrical connection from the air flow meter.

NameConnector
1Air flow meter  K41 
2. Undo the nuts (2s) and remove the brackets (2b) securing the air flow meter to the aiar filter cover.3. Remove the air flow meter (3a), complete with hose (3b).
Refitting ( Removing ) Refit the air flow meter in its seating complete with hose, then secure it using the brackets and nuts. Connect the electrical connection to the air flow meter.Proceed with refitting  - 1048A28  vacuum air circuit resonator pipe - r+r .Connect the negative (-) battery terminal.