3026074 - 5580CB Passenger BAG, SIDE BAG and HEAD BAG check
Disconnect the Bag connector
at the line involved and connect the special line closure resistor. Connect the Examiner to the diagnostic socket.Cancel the errors and check that they have disappeared.If the error persists, search for the fault in the wiring or
in the control unit.If the error does not reoccur, the fault should be sought in
the Bag.Reconnect the connector.