3026049 - 1040AA Check supply voltage and absorption current

Measure the pump supply voltage at the pump connector.Measure the pump absorption current by positioning the ammeter pliers zeroed and set to 200mv on the pump supply cable on the fuse box.  See E5050  DIESEL ENGINES ELECTRONIC MANAGEMENT