|  |  | Results of the tests | 
| 1 | CHECKING  WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
|---|
|  | Connect
the diagnostic equipment (Examiner) to the diagnostic socket.Check that there are no faults in the climate control system
control unit | Continue to Step 2 | An error is detected in
the control unit | Continue following the instructions for the diagnostic
equipment | 
| Communication lost with control unit - CAN line error | Restore connection between climate control system control unit
and body computer  See   E6020  AIR CONDITIONING | 
| 2 | ACTIVE DIAGNOSIS WITH DIAGNOSTIC
EQUIPMENT | All
OK | Problems
met | Operation | 
|---|
|  | Using
the diagnostic equipment (Examiner or other instruments), carry
out active diagnosis for the electric fan at different speeds | Continue to Step 3 | Electric fan connection
fault | Restore
the correct connection   See   E6020  AIR CONDITIONING | 
| Electric fan faulty | Replace fan  Op.   5040C30 | 
| 3 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation | 
|---|
|  | Check